Correlation Between Degree of Lens Opacity and the Phacoemulsification Energy Parameters Using Different Imaging Methods in Age-Related Cataract

TRANSLATIONAL VISION SCIENCE & TECHNOLOGY(2022)

引用 5|浏览7
暂无评分
摘要
Purpose: To compare the correlation between degree of lens opacity and the phacoemulsification energy parameter in patients with age-related cataract as determined by slit lamp, 25-MHz ultrasound biomicroscopy (UBM), and Scheimpflug imaging (Pentacam) and to evaluate the application of these three methods to measuring lens opacification. Methods: This observational study was conducted in 319 patients (381 eyes) with different types of age-related cataract. The average age of patients was 67.3 +/- 11.4 years. The degree of lens opacity acquired by slit lamp, 25-MHz UBM, and Pentacam was determined by the Lens Opacity Classification System III (LOCSIII), pixel units calculated by ImageJ, and lens density, respectively. We primarily analyzed and compared the correlation between lens opacity and the cumulative dissipated energy (CDE) values of phacoemulsification. Results: Cortical, nuclear, and posterior subcapsular (PSC) cataracts were evaluated as follows: LOCSIII grades 3.31 +/- 1.42, 3.29 +/- 1.49, and 0.91 +/- 0.83; pixel units 120.91 +/- 22.8, 93.2 +/- 15.9, and 99.7 +/- 13.0; and lens density 51.8 +/- 31.2, 21.2 +/- 6.10, and 53.3 +/- 35.3, respectively. The CDE values were 12.1 +/- 12.4, 13.5 +/- 9.11, and 3.93 +/- 1.96. In cortical cataract, there was a linear correlation among LOCSIII, pixel units, and CDE value (r = 0.560, r = 0.832, and r = 0.582, respectively; both P < 0.05), but lens density had no correlation with other parameters. In nuclear cataract, there was a linear correlation among LOCSIII, lens density, and CDE value (r = 0.747, r = 0.865, and r = 0.906, respectively; both P < 0.05), but pixel units had no correlation with other parameters. In PSC, only pixel units and LOCSIII showed a correlation. Conclusions: The various imaging methods offered different advantages in terms of determining lens opacity, a feature related to types of age-related cataracts. Choosing the most suitable imaging method to evaluate lens opacification based on the type of age-related cataract is important for accurately predicting the phacoemulsification parameters for cataract surgery. Translational Relevance: Determining the appropriate phacoemulsification strategy depends on quantitative analysis of the degree of lens opacity to reduce intraoperative and postoperative complications and to obtain the optimal postoperative visual outcome.
更多
查看译文
关键词
25-MHz UBM,degree of lens opacity,CDE value,Pentacam,cataract
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要