Hydrogen damage in a power boiler: A study of damage selectivity and conditions

Engineering Failure Analysis(2023)

引用 3|浏览0
暂无评分
摘要
•Selective hydrogen damage was observed in two boiler evaporator tubes.•A transient reduction in water quality initiated the corrosion and hydrogen damage.•A thick iron oxide scale was formed, which weakened the tube.•Thin evaporation residue accumulated on older tubes had a protective effect.•Scale removal with acid may worsen selective corrosion in hydrogen-damaged areas.
更多
查看译文
关键词
1- Field of engineering (mandatory, Choose one),Power generation,2- Name of component or system (mandatory, choose one),Boiler,3- Component material (mandatory, choose one),Steel,4- Component manufacturing process (non-mandatory, choose one),Electric resistance welding (ERW),5- The principal methodology (mandatory, choose one),Microscopic characterisation and microanalysis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper