Sequence-Admittance Measurement Method of Grid-Connected Inverter with Its Control System Disturbance

IEEE Transactions on Industrial Electronics(2022)

引用 1|浏览2
暂无评分
摘要
The impedance or admittance characteristics of the grid-connected inverter play an important role in its stability analysis. The traditional sequence-admittance measurement methods of the grid-connected inverter mostly rely on special admittance measurement equipment or adjacent grid-connected inverters for disturbance injection. Because of high hardware cost or inconvenience, the abovementioned methods are not suitable for price-conscious testers to some extent. To address the abovementioned issues, this article proposes a sequence-admittance measurement method of the grid-connected inverter with its control system disturbance. First, the sequence-admittance model of the measured grid-connected inverter when small-disturbance signal is superimposed on its modulation signal is deduced and the system equivalent circuit model is built. Then, the flow chart of the proposed sequence-admittance measurement method is designed. According to the injected small-disturbance signal, the output voltage and inductor current of the grid-connected inverter, the sequence-admittance characteristics in sub/supersynchronous frequency area can be obtained. The measurement process does not need the cooperation of external disturbance source, which saves costs and improves the measurement convenience. Finally, experiments verify the effectiveness of the proposed sequence-admittance measurement method.
更多
查看译文
关键词
inverter,sequence-admittance,grid-connected
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要