Determination of optimal tip position of peripherally inserted central catheters using electrocardiography: a retrospective study.

Korean journal of anesthesiology(2022)

引用 0|浏览7
暂无评分
摘要
BACKGROUND:Accurate tip positioning of a peripherally inserted central catheter (PICC) is crucial for optimal drug delivery and avoiding complications. The objective of this study was to evaluate the amplitude ratios of intravascular electrocardiography (ivECG) and external electrocardiography (exECG) according to the tip location. METHODS:This retrospective study analyzed ivECG, exECG, and chest X-ray (CXR) of 278 patients who underwent a PICC procedure. The tip-to-carina distance (TCD) was measured using vertebral body units (VBU) on CXR. Tip locations were categorized as follows: Zone 1, malposition (TCD < 0.8 VBU); Zone 2, suboptimal (0.8 VBU ≤ TCD < 1.5 VBU); Zone 3, optimal (1.5 VBU ≤ TCD ≤ 2.4 VBU); Zone 4, deep (TCD > 2.4 VBU). The amplitude ratios between ivECG and exECG and within ivECG were compared in each zone. RESULTS:The ivECG/exECG amplitude ratios of P-wave (Piv/Pex) and QRS-complex (QRiv/QRex and RSiv/RSex) in Zone 3 were significantly higher than in Zones 1 and 2 (adjusted P < 0.05). The ivECG amplitude ratios of the P-wave and QRS-complex (Piv/QRiv and Piv/RSiv) were significantly lower in Zone 3 than in Zones 1 and 2 (adjusted P < 0.001). The calculated TCD using stepwise multiple regression analysis was estimated to be 1.121 + 0.078 × Piv/Pex - 0.172 × Piv/QRiv. CONCLUSIONS:Though caution is required, amplitude ratios such as Piv/Pex and Piv/QRiv can help determine tip location during the PICC catheterization procedure.
更多
查看译文
关键词
Carina,Central Catheterization,Electrocardiogram,Peripherally Inserted Central Catheter Line Insertion,Vertebral body,X-Ray
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要