The triggerless data acquisition system of the XENONnT experiment

E. Aprile, J. Aalbers, K. Abe, F. Agostini,S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino,J. R. Angevaare,V. C. Antochi, D. Anton Martin,F. Arneodo,L. Baudis, A. L. Baxter,L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner,G. Bruno,R. Budnik,T. K. Bui, C. Cai,J. M. R. Cardoso, D. Cichon,A. P. Cimental Chavez, D. Coderre,A. P. Colijn,J. Conrad, J. J. Cuenca-Garcia,J. P. Cussonneau,V. D'Andrea,M. P. Decowski,P. Di Gangi, S. Di Pede, S. Diglio,K. Eitel,A. Elykov, S. Farrell, A. D. Ferella,C. Ferrari,H. Fischer, M. Flierman, W. Fulgione, C. Fuselli, P. Gaemers, R. Gaior,A. Gallo Rosso,M. Galloway,F. Gao, R. Glade-Beucke,L. Grandi, J. Grigat,M. Guida,R. Hammann,A. Higuera, C. Hils, L. Hoetzsch,N. F. Hood,J. Howlett,M. Iacovacci, Y. Itow,J. Jakob, F. Joerg,A. Joy,N. Kato,M. Kara,P. Kavrigin,S. Kazama,M. Kobayashi, G. Koltman, A. Kopec, F. Kuger, H. Landsman, R. F. Lang,L. Levinson, I. Li, S. Li,S. Liang, S. Lindemann, M. Lindner,K. Liu, J. Loizeau,F. Lombardi,J. Long,J. A. M. Lopes,Y. Ma, C. Macolino, J. Mahlstedt, A. Mancuso,L. Manenti,F. Marignetti,T. Marrodan Undagoitia,K. Martens,J. Masbou,D. Masson, E. Masson,S. Mastroianni,M. Messina, K. Miuchi, K. Mizukoshi, A. Molinario,S. Moriyama,K. Mora, Y. Mosbacher, M. Murra, J. Mueller,K. Ni,U. Oberlack, B. Paetsch,J. Palacio,R. Peres, C. Peters,J. Pienaar,M. Pierre, V. Pizzella, G. Plante, J. Qi,J. Qin,D. Ramirez Garcia, A. Rocchetti,L. Sanchez,P. Sanchez-Lucas,J. M. F. dos Santos,I. Sarnoff, G. Sartorelli, J. Schreiner, D. Schulte,P. Schulte,H. Schulze Eissing,M. Schumann,L. Scotto Lavina,M. Selvi, F. Semeria, P. Shagin,S. Shi, E. Shockley,M. Silva, H. Simgen, A. Takeda, P. -L. Tan, A. Terliuk,D. Thers, F. Toschi, G. Trinchero,C. Tunnell, F. Toennies, K. Valerius,G. Volta, C. Weinheimer, M. Weiss, D. Wenz,C. Wittweg,T. Wolf, D. Xu, Z. Xu, M. Yamashita,L. Yang,J. Ye, L. Yuan, G. Zavattini, S. Zerbo,M. Zhong,T. Zhu

JOURNAL OF INSTRUMENTATION(2023)

引用 0|浏览19
暂无评分
摘要
The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commercially available hardware accompanied by open-source and custom-developed software. The three constituent subsystems of the XENONnT detector, the TPC (main detector), muon veto, and the newly introduced neutron veto, are integrated into a single DAQ, and can be operated both independently and as a unified system. In total, the DAQ digitizes the signals of 698 photomultiplier tubes (PMTs), of which 253 from the top PMT array of the TPC are digitized twice, at x10 and x0.5 gain. The DAQ for the most part is a triggerless system, reading out and storing every signal that exceeds the digitization thresholds. Custom-developed software is used to process the acquired data, making it available within 30 s for live data quality monitoring and online analyses. The entire system with all the three subsystems was successfully commissioned and has been operating continuously, comfortably withstanding readout rates that exceed 500 MB/s during calibration. Livetime during normal operation exceeds 99% and is 90% during most high-rate calibrations. The combined DAQ system has collected more than 2 PB of both calibration and science data during the commissioning of XENONnT and the first science run.
更多
查看译文
关键词
Dark Matter detectors (WIMPs,axions,etc),Data acquisition concepts,Data processing methods,Front-end electronics for detector readout
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要