Co-attention spatial transformer network for unsupervised motion tracking and cardiac strain analysis in 3D echocardiography

MEDICAL IMAGE ANALYSIS(2023)

引用 1|浏览7
暂无评分
摘要
Myocardial ischemia/infarction causes wall-motion abnormalities in the left ventricle. Therefore, reliable motion estimation and strain analysis using 3D+time echocardiography for localization and characterization of myocardial injury is valuable for early detection and targeted interventions. Previous unsupervised cardiac motion tracking methods rely on heavily-weighted regularization functions to smooth out the noisy displacement fields in echocardiography. In this work, we present a Co-Attention Spatial Transformer Network (STN) for improved motion tracking and strain analysis in 3D echocardiography. Co-Attention STN aims to extract inter-frame dependent features between frames to improve the motion tracking in otherwise noisy 3D echocardiography images. We also propose a novel temporal constraint to further regularize the motion field to produce smooth and realistic cardiac displacement paths over time without prior assumptions on cardiac motion. Our experimental results on both synthetic and in vivo 3D echocardiography datasets demonstrate that our Co-Attention STN provides superior performance compared to existing methods. Strain analysis from Co-Attention STNs also correspond well with the matched SPECT perfusion maps, demonstrating the clinical utility for using 3D echocardiography for infarct localization.
更多
查看译文
关键词
Echocardiography,Spatiotemporal attention,Unsupervised motion tracking
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要