Blood Pressure Estimation From Korotkoff Sound Signals Using an End-to-End Deep-Learning-Based Algorithm.

IEEE Transactions on Instrumentation and Measurement(2022)

引用 4|浏览8
暂无评分
摘要
While measurement of blood pressure (BP) is now widely carried out by automated noninvasive BP (NIBP) monitoring devices, as they do not require skilled clinicians and do not carry the risk of complications, their accuracy is in doubt. A novel end-to-end deep-learning-based algorithm was developed in this study that estimates NIBP directly from sequences of Korotkoff sounds (KSs) rather than oscillometric waveforms (OWs). First, sequences of segments of KSs were formed using different signal segmentation techniques, that is, segmentation using a sliding window with or without overlap and segmentation using the cardiac period estimation. Each segment within each sequence was then labeled as 1) after-systolic and before-diastolic (AB) or 2) before-systolic or after-diastolic (BA) such that a binary sequence-to-sequence classification problem was achieved. To deal with the resultant sequence-to-sequence classification problem, an algorithm was developed by combining 1-D convolutional neural networks (CNNs) and recurrent neural networks (RNNs). The segments associated with systolic and diastolic BP (SBP and DBP) are then identified as the segments at which the output target sequence switches from class BA to class AB and later from class AB to class BA. Lastly, the values of SBP and DBP are obtained by mapping the center point of the switching segments to the deflation curve. To evaluate the performance of the proposed NIBP estimation method, we used a database of 350 NIBP samples collected from 155 participants (87 males, age: 23-97 years, arm circumference: 10-35 cm, SBP: 81-104 mmHg, and DBP: 37-104 mmHg), and the achieved estimation errors for SBP and DBP, relative to the reference values, using a fivefold cross-validation approach, were 1.6 +/- 3.9 mmHg (mean absolute error +/- standard deviation of error) and 2.5 +/- 4.0 mmHg, respectively. We finally conclude that the proposed end-to-end deep-learning-based NIBP estimation algorithm from sequences of KSs is a novel technique that requires modest preprocessing steps and can measure BP accurately.
更多
查看译文
关键词
Estimation,Monitoring,Biomedical monitoring,Blood pressure,Feature extraction,Visualization,Protocols,Auscultatory noninvasive blood pressure (NIBP) monitoring devices,combined convolutional neural networks (CNNs) and bidirectional long short-term memory recurrent neural networks (LSTM-RNNs),deep-learning-based NIBP estimation,Korotkoff sounds (KSs),noninvasive systolic and diastolic BP (SBP and DBP) estimation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要