High-Performance Anion-Exchange chromatography with conductivity detection method for simultaneous determination of nitrogen and phosphorus in polysaccharides

JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES(2022)

引用 0|浏览3
暂无评分
摘要
Capsular polysaccharides of Streptococcus pneumoniae contain a characteristic mix of monosaccharides in their structure resulting in immunologically distinct serotypes. Pneumococcal capsular polysaccharides include sugars such as hexoses, uronic acids, hexosamines, methyl pentoses, other functional groups are attached to the sugars are N and O-acetyl groups, nitrogen and phosphorus. Most of these components can be quantified using different colorimetric methods. However, available methods for quantifying nitrogen and phosphorus are not sensitive enough and laborious. We report a highly sensitive high-performance anion-exchange chromatographyconductivity detector (HPAEC-CD) method for quantifying nitrogen and phosphorus present in pneumococcal capsular polysaccharides. The method is reliable, robust and reproducible with no interference. The LOQ for nitrogen and phosphorus of 3.125 and 62.5 ng/mL, respectively, is highly critical for estimating low levels of total nitrogen and total phosphorus. We have implemented this method to quantify total nitrogen in Typhoid Vi polysaccharide and phosphorus in Haemophilus influenzae type-b polysaccharide. This method has greater application for quantification of nitrogen and phosphorus present in low concentrations in polysaccharide vaccines/biologicals.
更多
查看译文
关键词
Polysaccharides,Pneumococcal vaccines,Nitrogen,Phosphorus,HPAEC-CD
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要