Hazmat Cooling Vest Temperature Using Heat Pipe and Thermoelectric

Septiadi Wayan Nata,Dwipayana Anak Agung Gde Agung Krisnanta,Marianti Komang Manik, Nugraha I Ketut Arya Aditya, Shantika I Made Pujanu Ary, Ananta I Gede Riski, Suarsana I Komang Wahyu,Fatmawati Ni Nengah Dwi,Sulistiowati Ni Made Dian,Putra Nandy

Proceedings of the 3rd International Conference on Experimental and Computational Mechanics in Engineering(2022)

引用 0|浏览2
暂无评分
摘要
Corona Virus (COVID-19) is a virus that is endemic almost all over the world, including Indonesia. COVID-19 was first confirmed by the World Health Organization (WHO) on December 31, 2019, in Wuhan City, Hubei Province, China, and then rapidly expanded outside of China. To suppress the Covid-19 case, medical volunteers are needed as the main actors in efforts to handle Covid-19 patients. This makes health care facilities also need to focus on the principles of health worker safety, not only focus on the principles of patient safety. This also makes health care facilities also need to focus on the principles of health worker safety, not only focus on the principles of patient safety. The use of hazmat clothes is one of the efforts to protect health workers when in contact with Covid-19 patients. Hazmat clothes are technically referred to as “encapsulated waterproof protective clothing” which is PPE that must be used for officers from the risk of contracting the Covid-19 virus through airborne droplets and contact with patients and patient body fluids. Although hazmat clothing is an important PPE for health workers to stay protected, the use of hazmat clothing for a long time often makes medical personnel feel uncomfortable when providing services. Based on the problems above, the researchers conducted a study on the heat pipe - thermoelectric hazmat suit cooling vest. This technology can absorb more heat than other methods by simply applying the principle of capillarity to the wicks on the pipe walls. schematic of testing a cooling vest on a hazmat suit. The loading on the thermoelectric is given through the DC - Power supply. The temperature data read by the sensor will be detected by the computer system using the NI 9123 and C-DAQ 9174 modules. The test results can be viewed using the NI LabView 2017 software. The temperature used in this experiment is the result of tests carried out for 30 min. Based on the tests that have been carried out, the heat pipe-based thermoelectric hazmat suit cooling vest has been able to reach the lowest thermoelectric temperature of 24,42  $$^\circ{\rm C} $$ , which is distributed through heat pipes to body parts.
更多
查看译文
关键词
Heat pipe, Thermoelectric, Cooling vest, Hazmat
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要