The Collection Efficiency of a Large Area PMT Based on the Coated MCPs

MEASUREMENT SCIENCE REVIEW(2022)

引用 0|浏览3
暂无评分
摘要
The electron collection efficiency (CE) of the photomultiplier tube based on microchannel plates (MCP-PMT) is limited by the MCP open area fraction. Coating MCP with a high secondary yield material is supposed to be an effective approach to improve CE. Both typical and coated MCP-PMTs are developed. A relative measurement method is proposed to characterize the collection efficiency performance. Results show that the PMT based on the coated MCPs has a significant improvement on CE, a good gain uniformity and a high precise energy resolution.
更多
查看译文
关键词
Photomultiplier tube, Microchannel plate, Collection efficiency