An In vitro Assessment of Retention Force of ZrO2, Polyether Ether Ketone, and ZrO2-Polyether Ether Ketone Telescopic Attachment for Mandibular Overdentures.

Journal of pharmacy & bioallied sciences(2022)

引用 0|浏览1
暂无评分
摘要
Objectives:The objective of this study was to compare ZrO2, polyether ether ketone (PEEK), and ZrO2-PEEK telescopic attachments in terms of retention of overdenture. Methodology:Forty-five acrylic resin models of the lower arch were divided into 3 groups of 15 each. In Group I, primary and secondary crowns were constructed from all zirconia (ZrO2), whereas all PEEK was used for Group II and Group III was made up of ZrO2 PEEK. Results:The mean retention value in Group I was 14.12 ± 3.4 N, in Group II was 15.86 ± 5.1, and in Group III was 22.40 ± 10.3 N. The mean final initial retention value in Group I was 14.50 ± 6.1 N, in Group II was 14.97 ± 8.2, and in Group III was 17.21 ± 9.3 N. A significant difference was observed in intergroup comparison (P < 0.05). Conclusion:Zirconia resulted in maximum retention as compared to other telescopic crown materials.
更多
查看译文
关键词
Initial force,telescopic crown,zirconia oxide
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要