INFLUENCE OF SAMPLING FLOW RATE ON THORON EXHALATION RATE MEASUREMENTS BY THE CIRCULATION METHOD

RADIATION PROTECTION DOSIMETRY(2022)

引用 3|浏览8
暂无评分
摘要
Researchers have used various methods to obtain the exhalation rates of radon and thoron from soil and building materials. One of the typical methods for radon exhalation rate is the circulation method using an accumulation container, an external or internal sampling pump and a continuous radon monitor. However, it is necessary to consider sampling flow rate if this method is applied to exhalation rate measurement for thoron due to its short half-life. Based on a calibration experiment, the measured thoron concentrations obtained by an electrostatic collection type radon and thoron monitor (RAD7) were found to be influenced strongly by the sampling flow rate. It was also found that the thoron exhalation rate from a soil sample depended on the pressure difference which was proportional to the increasing sampling flow rate. The thoron exhalation rate measured at the generally used sampling flow rate of the internal sampling pump of the RAD7 was overestimated compared with the value at 0 L min(-1).
更多
查看译文
关键词
thoron exhalation rate measurements,sampling flow rate,circulation method