Single-Unit Short Implants in the Molar Region: A Retrospective Study with a Minimum 3-Year Follow-up.

The International journal of periodontics & restorative dentistry(2022)

引用 0|浏览0
暂无评分
摘要
The high biomechanical loads in molar region wounds challenge the indication for short implants to be used as a single-unit implant. This study reports on the outcomes of single-unit short implants (≤ 8.0 mm) in the maxillary and mandibular molar regions. Forty-nine short implants were placed in 48 patients to replace a missing molar tooth. Two-piece restorations with screw retention were fabricated. During the follow-up, implant survival and marginal bone loss (MBL) were assessed. The known implant length was used as a reference to calibrate the linear measurements on digital periapical radiographs, and descriptive statistical analysis was performed. The implants were followed over a period of 47 ± 12 months. No implant failure was recorded, and no prosthesis failure was observed. The average MBL was 0.15 ± 0.5 mm. The mean crown height space was 13 ± 3 mm. The overall crown-to-implant ratio was 1.7 ± 0.4. Two technical complications occurred due to the loosening of the unit abutment. After screw re-tightening, no more screw loosening was observed. This study supports the use of short implants as a single-unit implant in the maxillary and mandibular molar regions.