Magnetic Cooling and Vibration Isolation of a Sub-kHz Mechanical Resonator

Journal of Low Temperature Physics(2023)

引用 0|浏览10
暂无评分
摘要
We report recent progress toward the realization of a sub-mK, low-vibration environment at the bottom stage of a dry dilution refrigerator for use in mechanical tests of quantum mechanics. Using adiabatic nuclear demagnetization, we have cooled a silicon cantilever force sensor to T≈ 1 mK. The temperature of the tip holder of the cantilever chip was determined via a primary magnetic flux noise thermometer. The quality factor of the cantilever continues to increase with decreasing temperature, reaching Q≈ 4· 10^4 at 2 mK. To demonstrate that the vibration isolation is not compromised, we report the detection of the thermal motion of the cantilever down to T ≈ 20 mK, only limited by the coupling to the SQUID readout circuit. We discuss feasible improvements that will allow us to probe unexplored regions of the parameter space of continuous spontaneous localization models.
更多
查看译文
关键词
MRFM,Vibration isolation,Mechanical oscillator,Noise thermometry,Adiabatic nuclear demagnetization
AI 理解论文