Continuously tunable radio frequency electrometry with Rydberg atoms

APPLIED PHYSICS LETTERS(2022)

引用 15|浏览3
暂无评分
摘要
We demonstrate a continuously tunable electric field measurement based on the far off-resonant AC stark effect in a Rydberg atomic vapor cell. In this configuration, a strong far off-resonant field, denoted as a local oscillator (LO) field, acts as a gain to shift the Rydberg level to a high sensitivity region. An incident weak signal field with a few hundreds of kHz difference from the LO field is mixed with the LO field in the Rydberg system to generate an intermediate frequency signal, which is read out by Rydberg electromagnetically induced transparency (Rydberg-EIT) spectroscopy. Not like resonant EIT-Autler-Townes spectra, we realize the electric field measurement of the signal frequency from 2 to 5 GHz using a single Rydberg state. The detectable field strength is down to 2.25 mu V/cm with sensitivity of the electrometry 712 nV cm(-1 )Hz(-1/2), and a linear dynamic range is over 65 dB. The detectable field strength is comparable with a resonant microwave-dressed Rydberg heterodyne receiver using the same system, which is 0.96 mu V/cm with sensitivity of 304 nV cm(-1 )Hz(-1/2). We also show the system has an inherent polarization selectivity feature. Our method can provide high sensitivity of electric field measurement and be extended to arbitrary frequency measurements. C2022 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).