Color M-Mode Echocardiography for Non-Invasive Assessment of the Intraventricular Pressure in Dogs Before and After Ductus Arteriosus Occlusion: A Retrospective Study

FRONTIERS IN VETERINARY SCIENCE(2022)

引用 5|浏览8
暂无评分
摘要
BackgroundNovel non-invasive evaluation of the intraventricular pressure differences and gradients (IVPD and IVPG) by color M-mode echocardiography (CMME) is a promising method in diastolic function evaluation. Patent ductus arteriosus (PDA) is a congenital heart defect which is associated with increased preload. The present work provides a clinical trial for the assessment of IVPD and IVPG changes in dogs before and after surgical occlusion of PDA. Materials and MethodsA total of 12 client-owned dogs were enrolled in this study. PDA was confirmed using echocardiography, and all dogs underwent PDA occlusion. Conventional echocardiography and CMME were conducted on each patient on the operation day (Pre-PDA) and 48 h after its occlusion (Post-PDA). The total IVPD and total IVPG, as well as segmental intraventricular pressure (basal, mid-to-apical, mid, and apical) were measured from Euler's equation using specific software (MATLAB). Data were analyzed for variability and for the difference between pre- and post-PDA. The effect of PDA occlusion on the measured variables was calculated using biserial ranked correlation (rc). ResultsThere was a significant reduction in end-diastolic volume, fraction shortening, stroke volume, and mitral inflow velocities (early and late) after PDA closure. CMME was feasible in all dogs, and the CMME indices showed moderate variability, except for the apical segment of IVPD and IVPG. After PDA closure, in comparison with the pre-PDA occlusion, there was a significant reduction in total IVPD (2.285 +/- 0.374 vs. 1.748 +/- 0.436 mmHg; P = 0.014), basal IVPD (1.177 +/- 0.538 vs. 0.696 +/- 0.144 mmHg; P = 0.012), total IVPG (1.141 +/- 0.246 vs. 0.933 +/- 0.208 mmHg; P = 0.032), and basal IVPG (0.578 +/- 0.199 vs. 0.377 +/- 0.113 mmHg; P = 0.001); meanwhile, mid, mid-to-apical, and apical segments of both IVPD and IVPG showed non-significant difference. The magnitude of PDA occlusion on the measured variables was clinically relevant and associated with a large effect size on total and basal IVPD and IVPG (rc > 0.6). ConclusionThe current clinical study revealed matched response of IVPD and IVPG to the reduced preload rather than left ventricular relaxation. This result is an initial step in the clinical utility of CMME-derived IVPD and IVPG measurements in the diastolic function evaluation in dogs with PDA that warrants further clinical studies.
更多
查看译文
关键词
dog, ductus arteriosus, Doppler echocardiography, intraventricular pressure, diastole, overloading
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要