Effect of different contrast medium injection protocols for analysis of hepatic computed tomography perfusion in healthy dogs

AMERICAN JOURNAL OF VETERINARY RESEARCH(2022)

引用 1|浏览4
暂无评分
摘要
OBJECTIVE To evaluate the hepatic CT perfusion (CTP) for determining the appropriate protocol for the dual-input maximum- slope model in dogs. ANIMALS 5 healthy dogs. PROCEDURES Each dog underwent CTP with different contrast medium administration protocols. Combinations of three different injected doses of iohexol (450, 600, and 750 mg/kg) and injection durations (5, 10, and 15 seconds) were used. The CT values at the aorta, portal vein, and hepatic parenchyma were measured to create a time-density curve, and CTP parameters were measured simultaneously on each hepatic lobe using a 320-row multidetector CT scanner. RESULTS The maximum peak enhancement at the aorta, portal vein, and hepatic parenchyma was greater with the 750-mg/kg dose than with the 450-mg/kg dose. With an injection duration of 15 seconds, the aortic enhancement peak was less, and the arrival time at the aortic enhancement peak was longer compared to that with a 5-second injection duration. The CTP parameters in the caudate process of the caudate lobe and left lateral lobe differed with different injection durations. The CTP parameters in the caudate process of the caudate lobe, left lateral lobe, and right lateral lobe differed with varying injected doses.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper