Radiobiological Comparison of Acuros External Beam and Anisotropic Analytical Algorithm on Esophageal Carcinoma Radiotherapy Treatment Plans

DOSE-RESPONSE(2022)

引用 0|浏览4
暂无评分
摘要
Objective: The present study aimed to investigate the dose differences and radiobiological assessment between Anisotropic Analytical Algorithm (AAA) and Acuros External Beam (AXB) with its 2 calculation models, namely, dose-to-water (AXB-Dw) and dose-to-medium (AXB-Dm), on esophageal carcinoma radiotherapy treatment plans. Materials and methods: The AXB-Dw and AXB-Dm plans were generated by recalculating the initial 66 AAA plans using the AXB algorithm with the same monitor units and beam parameters as those in the original plan. The dosimetric and radiobiological assessment parameters were calculated for the planning target volume (PTV) and organs at risk (OARs). The gamma agreement for the PTV and the correlation between it and the volume of the air cavity and bone among the different algorithms were compared simultaneously. The dose discrepancy between the theoretical calculation and treatment planning system (TPS) when switching from AXB-Dm to AXB-Dw was analyzed according to the composition of the structures. Results: The PTV dose of AXB-Dm plans was significantly smaller than that of the AAA and AXB-Dw plans (P < .05), except for D-2. The difference values for AAA vs AXB-Dm ( increment D-x,D-(AAA-AXB,D-Dm)) and AXB-Dw vs AXB-Dm ( increment D-x,D-(AXB,D-Dw-AXB,D-Dm)) were 1.94% [1.27%, 2.64%] and 1.95% [1.56%, 2.27%], respectively. For the spinal cord and heart, there were obvious differences between the AAA vs AXB-Dm (spinal cord: 1.15%, heart: 2.89%) and AXB-Dw vs AXB-Dm (spinal cord: 1.88%, heart: 3.25%) plans. For the lung, the differences between AAA vs AXB-Dm and AAA vs AXB-Dw were significantly larger than those of AXB-Dm vs AXB-Dw. Compared to the case of AAA and AXB-Dw, the decrease in biologically effective dose (BED10, alpha beta=10 ) of AXB-Dm due to dose non-uniformity exceeded 6.5%, even for a small sigma. The average values of equivalent uniform dose in the AAA, AXB-Dw, and AXB-Dm plans were 52.03 +/-.39 Gy, 52.24 +/- .81 Gy, and 51.13 +/- .47 Gy, respectively. The tumor control probability (TCP) results for PTV in the AAA, AXB-Dw, and AXB-Dm plans were 62.29 +/- 1.57%, 62.82 +/- 1.69%, and 58.68 +/- 1.88%, respectively. With the 2%/2 mm and 3%/3 mm acceptance criteria, the mean values of Delta gamma(AXB-Dw)(AAA), Delta gamma(AXB-Dm)(AAA), and Delta gamma(AXB-Dw)(AXB-Dm) were 87.24, 63.3, and 64.81% vs 97.86, 91.77, and 89.25%, respectively. The dose discrepancy between the theoretical calculation and TPS when switching from AXB-Dm to AXB-Dw was approximately 1.63%. Conclusions: The AAA and AXB-Dw algorithms overestimated the radiobiological parameters when the tumor particularly consisted of nonuniform tissues. A relatively small dose difference could cause a significant reduction in the corresponding TCP. Dose distribution algorithms should be carefully chosen by physicists and oncologists to improve tumor control, as well as to optimize OARs protection.
更多
查看译文
关键词
radiobiological assessment, anisotropic analytical algorithm and acuros external beam, gamma passing rate, composition of the structures, esophageal carcinoma
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要