Automated semi-quantitative amyloid PET analysis technique without MR images for Alzheimer’s disease

Etsuko Imabayashi, Naoyuki Tamamura, Yuzuho Yamaguchi,Yuto Kamitaka,Muneyuki Sakata,Kenji Ishii

Annals of Nuclear Medicine(2022)

引用 2|浏览4
暂无评分
摘要
Objective Although beta-amyloid (Aβ) positron emission tomography (PET) images are interpreted visually as positive or negative, approximately 10% are judged as equivocal in Alzheimer’s disease. Therefore, we aimed to develop an automated semi-quantitative analysis technique using 18 F-flutemetamol PET images without anatomical images. Methods Overall, 136 cases of patients administered 18 F-flutemetamol were enrolled. Of 136 cases, five PET images each with the highest and lowest values of standardized uptake value ratio (SUVr) of cerebral cortex-to-pons were used to create positive and negative templates. Using these templates, PET images of the remaining 126 cases were standardized, and SUVr images were produced with the pons as a reference region. The mean of SUVr values in the volume of interest delineated on the cerebral cortex was compared to those in the CortexID Suite (GE Healthcare). Furthermore, centiloid (CL) values were calculated for the 126 cases using data from the Centiloid Project ( http://www.gaain.org/centiloid-project ) and both templates. 18 F-flutemetamol-PET was interpreted visually as positive/negative based on Aβ deposition in the cortex. However, the criterion "equivocal" was added for cases with focal or mild Aβ accumulation that were difficult to categorize. Optimal cutoff values of SUVr and CL maximizing sensitivity and specificity for Aβ detection were determined by receiver operating characteristic (ROC) analysis using the visual evaluation as a standard of truth. Results SUVr calculated by our method and CortexID were highly correlated ( R 2 = 0.9657). The 126 PET images comprised 84 negative and 42 positive cases of Aβ deposition by visual evaluation, of which 11 and 10 were classified as equivocal, respectively. ROC analyses determined the optimal cutoff values, sensitivity, and specificity for SUVr as 0.544, 89.3%, and 92.9%, respectively, and for CL as 12.400, 94.0%, and 92.9%, respectively. Both semi-quantitative analyses showed that 12 and 9 of the 21 equivocal cases were negative and positive, respectively, under the optimal cutoff values. Conclusions This semi-quantitative analysis technique using 18 F-flutemetamol-PET calculated SUVr and CL automatically without anatomical images. Moreover, it objectively and homogeneously interpreted positive or negative Aβ burden in the brain as a supplemental tool for the visual reading of equivocal cases in routine clinical practice.
更多
查看译文
关键词
Alzheimer’s disease,Automated Aβ-PET analysis,Centiloid,18F-flutemetamol-PET,Semi-quantitative Aβ analysis
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要