In Vitro Nasal Tissue Model for the Validation of Nasopharyngeal and Midturbinate Swabs for SARS-CoV-2 Testing

Devon R. Hartigan,Miryam Adelfio, Molly E. Shutt, Stephanie M. Jones, Shreya Patel, Joshua T. Marchand,Pamela D. McGuinness, Bryan O. Buchholz,Chiara E. Ghezzi

ACS Omega(2022)

引用 0|浏览0
暂无评分
摘要
Large-scale population testing is a key tool to mitigate the spread of respiratory pathogens, such as the current COVID-19 pandemic, where swabs are used to collect samples in the upper airways (e.g., nasopharyngeal and midturbinate nasal cavities) for diagnostics. However, the high volume of supplies required to achieve large-scale population testing has posed unprecedented challenges for swab manufacturing and distribution, resulting in a global shortage that has heavily impacted testing capacity worldwide and prompted the development of new swabs suitable for large-scale production. Newly designed swabs require rigorous preclinical and clinical validation studies that are costly and time-consuming (i.e., months to years long); reducing the risks associated with swab validation is therefore paramount for their rapid deployment. To address these shortages, we developed a 3D-printed tissue model that mimics the nasopharyngeal and midturbinate nasal cavities, and we validated its use as a new tool to rapidly test swab performance. In addition to the nasal architecture, the tissue model mimics the soft nasal tissue with a silk-based sponge lining, and the physiological nasal fluid with asymptomatic and symptomatic viscosities of synthetic mucus. We performed several assays comparing standard flocked and injection-molded swabs. We quantified the swab pickup and release and determined the effect of viral load and mucus viscosity on swab efficacy by spiking the synthetic mucus with heat-inactivated SARS-CoV-2 virus. By molecular assay, we found that injected molded swabs performed similarly or superiorly in comparison to standard flocked swabs, and we underscored a viscosity-dependent difference in cycle threshold values between the asymptomatic and symptomatic mucuses for both swabs. To conclude, we developed an in vitro nasal tissue model that corroborated previous swab performance data from clinical studies; this model will provide to researchers a clinically relevant, reproducible, safe, and cost-effective validation tool for the rapid development of newly designed swabs.
更多
查看译文
关键词
nasal tissue model,nasopharyngeal,midturbinate swabs,sars-cov
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要