Can Diffusion Tensor Imaging Apparent Diffusion Coefficient Diagnose Carpal Tunnel Syndrome? A Systematic Review and Meta-Analysis

HAND-AMERICAN ASSOCIATION FOR HAND SURGERY(2023)

引用 0|浏览8
暂无评分
摘要
Magnetic resonance diffusion tensor imaging (DTI) can detect microstructural changes in peripheral nerves. Studies have reported that the median nerve apparent diffusion coefficient (ADC), a quantification of water molecule diffusion direction, is sensitive in diagnosing carpal tunnel syndrome (CTS). Five databases were searched for studies using ADC to investigate CTS. Apparent diffusion coefficient (measured in mm2/s) were pooled in random-effects meta-analyses. Twenty-two studies met criteria yielding 592 patients with CTS and 414 controls. Median nerve ADC were measured at the level of the distal radioulnar joint (CTS ADC: 1.11, 95% CI: 1.07-1.15, I2 = 54%; control ADC: 1.04, 95% CI: 1.01-1.07, I2 = 57%), pisiform (CTS ADC: 1.39, 95% CI: 1.37-1.42, I2 = 0%; control ADC: 1.27, 95% CI: 1.23-1.31, I2 = 59%), hamate (CTS ADC: 1.40, 95% CI: 1.36-1.43, I2 = 58%; control ADC: 1.27, 95% CI: 1.25-1.28, I2 = 47%), and as an combination of several measurements (CTS ADC: 1.40, 95% CI: 1.37-1.47, I2 = 100%; control ADC: 1.39, 95% CI: 1.24-1.53, I2 = 100%). Median nerve ADC is decreased in individuals with CTS compared to controls at the levels of the hamate and pisiform. ADC cut-offs to diagnose CTS should be established according to these anatomic levels and can be improved through additional studies that include use of a wrist coil.
更多
查看译文
关键词
carpal tunnel syndrome,nerve,diagnosis,median nerve,diffusion tensor imaging,apparent diffusion coefficient,nerve compression
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要