Dosimetric Planning Comparison for Left-Sided Breast Cancer Radiotherapy: The Clinical Feasibility of Four-Dimensional-Computed Tomography-Based Treatment Planning Optimization

CUREUS JOURNAL OF MEDICAL SCIENCE(2022)

引用 1|浏览4
暂无评分
摘要
Background: Adjuvant whole-breast radiotherapy (RT) is a significant part of the standard of care treatment after breast cancer (BC) conserving surgery. Modem techniques including intensity-modulated radiation therapy (1MRT) and volumetric-modulated arc therapy (VMAT) have constituted to better target coverage and critical organs sparing. However, BC survivors are at risk of developing radiation-induced cardiac toxicity. Hence, deep-inspiration breath-hold (DIBH) techniques have been implemented at many centers to further reduce cardiac exposure but require compliance. 40-CT robust optimization can account for heart intrafractional motion per breathing phase. The optimization has been explored in cardiac sparing of breast IMRT compared to DIBH in a small sample size but has not been evaluated in substructures sparing, nor in VMAT. lb provide patients who are not compliant to breath-hold with an optimal treatment approach, various heart sparing techniques need to be evaluated for statistical significance and clinical feasibility. Aim: This retrospective study aimed to provide an extensive dosimetric heart sparing comparison of free-breathing, 4D-CT-based treatment planning, including robust optimization with DIBH-based treatment planning. Combinations of forward and inverse IMRT and VMAT are also considered. Methods: Fifteen early stage left-sided BC standard treatment plans were selected. Breast, lung, left anterior descending artery (LAD), left ventricle (LV), and the whole heart were contoured on each 4D-CT phase and DIBH CT dataset. Each treatment plan was optimized using forward/inverse I MRT and VMAT on the following CT datasets: DIBH, average 4D-CT, and the complete 4D-CT dataset needed for robust optimization. Dose-volume histograms were used to compare V(5Gy)Heart, mean heart dose, mean and max LAD dose, mean LV dose, and V-50% Lung. Results: All RT techniques assessed including 4D robust optimization were clinically feasible. Statistically significant differences in mean heart, LAD and LV dose, max LAD dose, and V(5Gy)Heart (p < 0.01) but no difference in V(50%)Lung (p = 0.29) were found between different techniques. IMRT DIBH achieved the optimal cardiac and substructure sparing among treatment plans. 4D robust IMRT had significantly greater mean heart and LV dose than DIBH IMRT (p <= 0.01), except LAD dose. Among free-breathing methods, no difference in all cardiac and substructure dose parameters was observed (p > 0.2) in comparing forward and inverse IMRT with average 4D-CT, inverse average 4D-CT, and 4D robust with IMRT, and between average 4D-CT VMAT and 4D robust VMAT. Only V(5Gy)Heart and mean LV dose were significantly greater in 4D robust VMAT (p < 0.01) compared to DIBH VMAT. Mean heart and LV doses were significantly reduced (p < 0.01) in DIBH IMRT compared to DIBH VMAT. Moreover, mean heart and LV dose, V(5Gy)Heart were significantly reduced in inverse IMRT average 4D-CT compared to average 4D-CT VMAT (p < 0.02) and in 4D robust IMRT compared to 4D robust VMAT (p < 0.04). Conclusion: This study demonstrated the clinical feasibility of 4D robust optimization in limiting the cardiac and substructures dose during free-breathing RT with both IMRT/VMAT for patients who are not compliant with breath-hold RT. However, this study also presents that 4D robust optimization can reduce LAD dose but not fully outperform DIBH or conventional 4D-CT-based planning with IMRT/VMAT in heart sparing in treating early staged left-sided BC patients.
更多
查看译文
关键词
distal left anterior descending artery (lad), left ventricle, deep-inspiration breath-hold, 4d-ct, dosimetric planning, cardiac, radiotherapy, left-sided breast cancer
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要