Intraocular lens-blocking technique for intraocular foreign body removal

INDIAN JOURNAL OF OPHTHALMOLOGY(2022)

引用 1|浏览3
暂无评分
摘要
The aim of this study was to describe a novel technique for intraocular foreign body (IOFB) removal. Phacoemulsification was performed in all patients, followed by a complete microincision vitrectomy to free all tissues surrounding the IOFB. A three-piece intraocular lens (IOL) was placed in the capsular bag, and an opening was made in the upper center of the capsule. The IOFB was removed and lifted to the anterior chamber through the capsular opening and IOL edge. The IOFB was confined to the anterior chamber by the IOL, and then easily extracted through the main corneal incision. The technique was adopted in six eyes of six patients. All IOFBs were removed successfully in all patients without intraoperative or postoperative complications. The IOL-blocking technique is a useful approach for IOFB removal.
更多
查看译文
关键词
Intraocular foreign body, intraocular lens-blocking, posterior capsulotomy