Minimally invasive reconstruction of acute acromioclavicular joint injuries using the TwinBridge button system

European journal of orthopaedic surgery & traumatology : orthopedie traumatologie(2022)

引用 2|浏览3
暂无评分
摘要
Introduction Acute acromioclavicular joint (ACJ) injuries are among the most common shoulder injuries in active young adults. The most frequently used surgical treatments include the hook plate implantation and arthroscopic treatment using flip-button systems. The aim of this study was to evaluate the results of treating acute ACJ injuries using a new minimally invasive implant based on a flip-button system. Material and methods From January 2016 to October 2019, a total of 20 patients with acute ACJ injuries (1 × Type III, 3 × Type IV, 16 × Type V) underwent surgery using the Twinbridge implant (Smith & Nephew). It is a prefabricated construct consisting of two Endobuttons connected with an UltraTape. One button is placed under the coracoid using a special aiming device and two buttons are placed on the clavicle. Preoperatively, 1 day postoperatively, 3 months and at least 1 year postoperatively, patients were clinically examined and bilateral stress view and axial radiographs were obtained. At final follow-up, the simple shoulder test (SST), Taft score, Constant score, and ACJ instability (ACJI) score were recorded and a side-to-side ratio of the coracoclavicular (CC) distance was calculated. Results All 20 patients were contacted at final follow-up at a mean of 28 (min. 13, max 50) months. Six patients were not willing to come for a clinical and radiographic examination and were contacted via telephone. All six patients were free of complaints. Another two patients free of complaints refused radiographs at final follow-up. The patients presented a mean SST of 99.6% (20 patients, min. 91.7, max. 100), Taft score of 11.6/12 points (12 patients, min. 10, max. 12), ACJI of 85.5/90 points (12 patients, min. 78, max. 90), and a Constant score of 97.1 (14 patients, min. 81.0, max. 100) for the affected shoulder. Preoperative stress view images revealed a mean side-to-side difference of the CC distance with a ratio of 1:2.34 (min. 1:1.80, max. 1:3.33). At final follow-up, CC distance was calculated with a mean ratio of 1:1.12 (min. 1.1, max. 1:1.38). Axial images showed a proper position in all cases. A “perfect” radiological result was achieved in six patients (50%) with a side-to-side CC distance of less than 10% (ratio 1:1.1 or less). A Rockwood type II result was achieved in five patients (42%) with a distance of 10 to 25% (ratio 1.11–1.25). One (8%) presented with a Rockwood type III result with a difference of more than 25% (ratio 1:1.38) and was considered a radiological failure. Conclusions When used correctly, the Twinbridge implant offers good-to-excellent clinical and radiographic results using a minimally invasive surgical technique. Complication rate is comparable to other button-systems.
更多
查看译文
关键词
Shoulder,Acromioclavicular,AC joint,Shoulder stabilization
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要