Certification of Uranium Isotope Amount Ratios in a Suite of Uranium Ore Concentrate Certified Reference Materials

GEOSTANDARDS AND GEOANALYTICAL RESEARCH(2022)

引用 5|浏览18
暂无评分
摘要
In this study, data from thirteen laboratories from around the world are presented for a successful certification of uranium isotope ratios in uranium ore concentrate (UOC) certified reference materials from the National Research Council Canada. Different mass spectrometric measurement principles (including SF-ICP-MS, quadruple ICP-MS, TIMS, MC-ICP-MS, SIMS and AMS) and measurement procedures were employed. In general, data from all sources exhibit good consistency with TIMS and MC-ICP-MS showing superior performance. The three candidate UOC CRMs (UCLO-1, UCHI-1 and UPER-1) have natural uranium isotope ratios with certified values of 0.5304(7) x 10(-4), 0.5475(2) x 10(-4) and 0.5361(4) x 10(-4) for n(U-234)/n(U-238) and 0.007 2563(13), 0.007 2563(10) and 0.007 2542(11) for n(U-235)/n(U-238), respectively, with expanded uncertainty (k = 2) applicable to the last digit of the value given in the parentheses. Information values for n(U-236)/n(U-238) in these three CRMs, measured by AMS, are also provided: 10 x 10(-12), 200 x 10(-12) and 22 x 10(-12). The uncertainties of the proposed certified values of uranium isotope ratios in UOC CRMs are superior to available reference materials, and the values of n(U-234)/n(U-238) and n(U-236)/n(U-238) show significant variation among the three CRMs.
更多
查看译文
关键词
MC-ICP-MS, TIMS, U isotope ratio, certified reference materials, uranium ore concentrate
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要