Delivery prediction by quantitative analysis of four steroid metabolites with liquid chromatography tandem mass spectrometry in asymptomatic pregnant women

ANNALS OF MEDICINE(2022)

引用 0|浏览8
暂无评分
摘要
Background: Prediction of delivery is important for assessing due dates, providing adequate prenatal care, and suggesting appropriate interventions in preterm and post-term pregnancies. Recent metabolomic findings suggested that the temporal abundance information of metabolome can be used to predict delivery timing with high accuracy in a cohort of healthy women. However, a targeted and quantitative assay is required to further validate the clinical performance and utility of this group of metabolomic candidates in delivery prediction with a larger and independent cohort. Method: LC-MS/MS quantitative assays were applied to determine the plasma concentrations of four steroid metabolites, including oestriol-16-glucuronide (E3-16-Gluc), 17-alpha-hydroxyprogesterone (17-OHP), tetrahydrodeoxycorticosterone (THDOC), and androstane-3,17-diol (A-3,17-Diol) in asymptomatic women of singleton pregnancies (>= 30th gestational weeks). Subsequent statistical analysis was conducted to assess the performance of the above candidates in delivery prediction. Result: Using LC-MS/MS, four steroids were separated and quantified in 5.5 min. The coefficients of variation (CVs) of the four analytes at the lower limit of quantification ranged from 7.9% to 14.6%, with the R-2 values greater than 0.990 in the calibration curves. Of the 585 recruited pregnant women who ended up with spontaneous delivery, 17.1% and 82.9% of the subjects delivered within and after 7 days since plasma collection, respectively. In the receiver operator curve analysis, the gestational age-adjusted area under the curve of the combined measurements of E3-16-Gluc and 17-OHP was 0.69 (95% CI: 0.60-0.76), with the sensitivity of 87.0% (95% CI: 78.8%-92.9%) and specificity of 60.2% (95% CI: 55.7%-64.6%). Moreover, the positive and the negative predictive values were 28.3%-34.0% and 93.1%-97.4% respectively for this combined panel. Conclusion: We performed analytical and clinical validation of a quantitation LC-MS/MS panel for the four steroids in the plasma of pregnant women. The steroid metabolites panel of E3-16-Gluc and 17-OHP was potentially useful for predicting delivery within one week in asymptomatic women of singleton pregnancies.
更多
查看译文
关键词
Delivery prediction, metabolism, LC-MS/MS, steroid, assay validation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要