Longitudinal Outcomes of Subcutaneous or Transvenous Implantable Cardioverter-Defibrillators in Older Patients

Journal of the American College of Cardiology(2022)

引用 7|浏览8
暂无评分
摘要
BACKGROUND The subcutaneous (S-) implantable cardioverter-defibrillator (ICD) is an alternative to the transvenous (TV-) ICD that is increasingly implanted in younger patients; data on the safety and effectiveness of the S-ICD in older patients are lacking. OBJECTIVES The purpose of this study was to compare outcomes among older patients who received an S-or TV-ICD. METHODS The authors compared S-ICD and single-chamber TV-ICD implants in Fee-For-Service Medicare beneficiaries using the National Cardiovascular Data Registry ICD Registry. Outcomes were ascertained from Medicare claims data. Cox regression or competing-risk models (with TV-ICD as reference) with overlap weights were used to compare death and nonfatal outcomes (device reoperation, device removal for infection, device reoperation without infection, and cardio-vascular admission), respectively. Recurrent all-cause readmissions were compared using Anderson-Gill models. RESULTS A total of 16,063 patients were studied (age 72.6 +/- 5.9 years, 28.4% women, ejection fraction 28.3 +/- 8.9%). Compared with TV-ICD patients (n = 15,072), S-ICD patients (n = 991, 6.2% overall) were more often Black, younger, and dialysis dependent and less likely to have history of atrial fibrillation or flutter. In adjusted analyses, there were no differences between device type and risk of all-cause mortality (HR: 1.020; 95% CI: 0.819-1.270), device reoperation (subdistribution [s] HR: 0.976; 95% CI: 0.645-1.479), device removal for infection (sHR: 0.614; 95% CI: 0.138-2.736), device reoperation without infection (sHR: 0.975; 95% CI: 0.632-1.506), cardiovascular readmission (sHR: 1.087; 95% CI: 0.912-1.295), or recurrent all-cause readmission (HR: 1.072; 95% CI: 0.990-1.161). CONCLUSIONS In a large representative national cohort of older patients undergoing ICD implantation, risk of death, device reoperation, device removal for infection, device reoperation without infection, and cardiovascular and all-cause readmission were similar among S-and TV-ICD recipients. (J Am Coll Cardiol 2022;79:1050-1059) Published by Elsevier on behalf of the American College of Cardiology Foundation.
更多
查看译文
关键词
implantable cardioverter-defibrillator,subcutaneous implantable cardioverter-defibrillator,sudden cardiac death
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要