Design procedure to bearing concrete failure in composite cold-formed steel columns with riveted bolt shear connectors

Engineering Structures(2022)

引用 2|浏览6
暂无评分
摘要
•Riveted bolt shear connectors used in composite cold-formed steel was investigated as load transfer device.•Numerical study was carried out with validation already proven in the literature.•Experimental and numerical results of the riveted bolt connectors were compared with design equations.•An analytical formulation of concrete bearing failure was proposed.
更多
查看译文
关键词
Concrete-filled steel tubes,Concrete bearing failure,Load introduction region,Load transfer,Composite structures,Bolted shear connectors
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要