Neutron yield measurement system of HL-2A tokamak

Plasma Science and Technology(2022)

引用 3|浏览16
暂无评分
摘要
This research presents the development of HL-2A neutron yield measurement which includes 235U fission chamber and BF3 and 3He proportional counters.Equivalent noise formula of the radiation detection signal amplification system was derived to guide the development of the signal amplification system.Then all detectors were calibrated in situ by using the 252Cf neutron source.The neutron yield of the HL-2A during neutral beam heating was analyzed.These results indicate that the developed neutron flux diagnostic system can obtain neutron yield results under various experimental conditions of the HL-2A tokamak,and can provide information on neutron yield.
更多
查看译文
关键词
HL-2A,neutron yield,neutron flux,fission chamber,in situ calibration,equivalent noise charge