Study on The Heat Dissipation Performance of Symmetrical Broken-line Microchannel Radiator

international conference on electronic packaging technology(2021)

引用 1|浏览0
暂无评分
摘要
In this paper, the heat dissipation of symmetrical broken-line microchannel radiator is analyzed. Firstly, the symmetrical broken-line microchannel model is established based on the ordinary broken-line microchannel model, and two models are simulated and compared under the same conditions to compare their heat dissipation capacity. Then, the symmetrical broken-line microchannel model is orthogonally optimized based on factors of the outer corner radius, pipe spacing and pipe width-height ratio. The heat dissipation capacity is analyzed with the average temperature of heat source as the characterization. This study provides theoretical guidance for subsequent microchannel cooling technology.
更多
查看译文
关键词
Cooling capacity,simulation,heat dissipation uniformity,symmetrical broken-line microchannel