CFD Simulation Research on Agglomeration between Coal-fired Ash Fine Particulate and Atomized Droplets

Yiquan Guo,Junying Zhang

E3S Web of Conferences(2020)

引用 0|浏览2
暂无评分
摘要
In this paper, a collision model between atomized droplets of agglomeration solution and particles is established. On this basis, the effects of flue gas temperature, atomized droplet diameter and other factors on the particle agglomeration process are studied. In addition, the evaporation model of agglomeration solution in the flue of a power plant is established for the coal-fired unit of power plant. Through CFD software, the variation of flow field velocity, temperature and pressure in the flue is simulated to determine whether the chemical agglomeration technology has negative impact on the actual operating conditions of the power plant. The simulation results show that the velocity and pressure of the flow field in the flue have no obvious change after the agglomerating agent is injected. Besides, the temperature drop of about 7°C. The droplets evaporate completely at a distance of 7-8 m after spraying. The evaporation time of droplets is within 1.6 s.