Mid-infrared DMD-based spectral-coding spectroscopy with a supercontinuum laser source

OPTICS EXPRESS(2022)

引用 3|浏览8
暂无评分
摘要
We present a mid-infrared spectroscopic system based on a spectral-coding approach enabled by a modified digital micromirror device (DMD). A supercontinuum source offering a confined mid-infrared laser beam is employed to perform gas measurements with this system. The performance, flexibility, and programmability enabled by the DMD is experimentally demonstrated by gas-cell measurements (CO2, CH4, N2O, NO2 and CO). Full spectra are acquired in 14 ms at 10 nm spectral resolution and in 3.5 ms at 40 nm spectral resolution. Further, we employ the system for stand-off open-path spatially resolved CO2 measurements that fully exploit the laser emission properties - the bright and highly-collimated supercontinuum beam is scanned by a galvo mirror over a retroreflector array at a scalable remote distance. The measurement concept models a passing gas emitter under lab conditions; time and spatially resolved CO2 absorbance gas-plume images in the mid-infrared range are obtained. (C) 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement