Impact of Power Converter Current Ripple on the Degradation of PEM Electrolyzer Performances

François Parache, Henri Schneider,Christophe Turpin,Nicolas Richet, Olivier Debellemanière,Éric Bru, Anh Thao Thieu, Caroline Bertail, Christine Marot

MEMBRANES(2022)

引用 14|浏览1
暂无评分
摘要
In this study, an endurance test of 3000 h was conducted on four equivalent proton exchange membrane (PEM) electrolyzers to identify and quantify the impact of an electric ripple current on their durability. Three different typical power converter waveforms and frequencies were explored. Signals were added to the same direct current carrier and also tested for reference. Performance comparison based on polarization curves and electrochemical impedance spectroscopy (EIS) analysis revealed that the ripple current favors degradation. Triangular waveform and a frequency of 10 kHz were identified as the most degrading conditions, leading to a sharp increase in high-frequency resistance (HFR) and the emergence of mass transport limitations due to the enhanced degradation of titanium mesh. Moreover, reversible losses were observed and further explorations are needed to decorrelate them from our observations.
更多
查看译文
关键词
PEM electrolyzer, ripple current, degradation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要