During the summer of 2019, cases of lung injury associated with vaping emerged in North America, including among individuals who reported exclusive use of nicotine vaping liquids. Once vitamin E acetate was identified as a potential causative agent a quantitative method based on a simple sample dilution, separation by gas chromatography and analysis by triple quadrupole mass spectrometry (GC MSMS) was developed. Method detection limit (MDL) and limit of quantification (LOQ) were determined at 0.159 µg/mL and 0.505 µg/mL, respectively. The analysis was performed on a subset of 203 commercially sourced nicotine containing vaping liquids of various flavour profile and nicotine range (nicotine free-59 mg/mL) from an internal inventory. The target analyte, Vitamin E Acetate, was not detected in any samples analyzed, as expected, given the reported detection in literature and high association of the chemical with cannabis and not nicotine containing vaping products.