Extensive model validation for generic IEC 61400-27-1 wind turbine models

R. Villena-Ruiz, A. Honrubia-Escribano, F. Jimenez-Buendia, J. L. Sosa-Avendano, S. Frahm, P. Gartmann,J. Fortmann,P. E. Sorensen,E. Gomez-Lazaro

International Journal of Electrical Power & Energy Systems(2022)

引用 6|浏览9
暂无评分
摘要
•A total of 59 voltage dip field tests are conducted in 7 different wind turbines.•3 leading manufacturers of wind turbines involved in the study.•Type 3A, 3B and 4A wind turbine models based on Standard IEC 61400-27-1 are validated.•The usefulness, practical applicability and accuracy of IEC 61400-27-1 is demonstrated.
更多
查看译文
关键词
DFIG,Full-converter,IEC 61400-27-1,Transient stability,Wind turbine model validation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要