Experimental Investigation Of The Microbubble Generation Using A Venturi-Type Bubble Generator

CASE STUDIES IN THERMAL ENGINEERING(2021)

引用 12|浏览5
暂无评分
摘要
This experimental study investigated how changes in the water flow rate affected the number and size of microbubbles using venturi with equal entry and exit angles of 30 degrees. The water flow rate ranged between 10 and 18 m(3)/h. Photos of microbubbles were taken with a digital camera in a visualized section that was specifically installed to store a certain amount of water to measure microbubble size and the number of microbubbles. The experimental results indicated that when the water flow rate increased, the airflow rate also increased. The microbubble size tended to decrease when the water flow rate increased; the sizes obtained were in the range of 50-130 mu m. The amount of air bubbles tended to increase when the water flow rate increased.
更多
查看译文
关键词
Microbubble, Microbubble generator, Venturi, Entry angle, Exit angle