An Alternative Technique For Verification Of Terahertz Smith-Purcell Radiation

P. Rattanawan, T. Chulapakorn, C. Tanapirom, P. Phukphan, N. Cota,K. Prasertsuk, J. Y. Chia, W. Kusolthossakul, R. Jintamethasawat

JOURNAL OF PHYSICS D-APPLIED PHYSICS(2021)

引用 1|浏览0
暂无评分
摘要
An alternative technique to verify terahertz (THz) Smith-Purcell radiation (SPR) was proposed by using different grating periods. A compact DC electron gun, serving as a THz source, was modified to generate continuous 35 keV electron beam that passes by a metal-coated silicon grating in order to induce SPR. A design on beam optics to generate high-brightness beam was carried out by using Computer Simulation Technology (CST) Studio Suite(R) software package. The optimization of beam parameters was obtained and experimentally performed. Results show that the root-mean-square (rms) beam size (diameter) is about 1 mm when supplying beam current of 200 mu A, and rms beam emittance is about 3 pi mm mrad. The CST simulation software was, furthermore, employed to observe radiation spectra when using different grating structures. A liquid-helium cooled silicon bolometer together with a low-pass filter was used to detect radiation power. The results reveal that incoherent THz signal with power of 1.5 mu W cm(-2) is observed when the continuous-beam current is about 200 mu A. The dependence of THz frequency and power on the grating period, that is associated to the SPR, was also investigated in this work.
更多
查看译文
关键词
compact DC electron gun, terahertz source, Smith-Purcell radiation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要