An Arm Isolation And Reconfiguration Fault Tolerant Control Method Based On Data-Driven Methodology For Cascaded Seven-Level Inverter

PROCEEDINGS OF 2018 IEEE 7TH DATA DRIVEN CONTROL AND LEARNING SYSTEMS CONFERENCE (DDCLS)(2018)

引用 6|浏览0
暂无评分
摘要
Inverts, especially multi-level inverters are widely used in many fields, such as industrial production, transportation, aviation and so on. So great significance should be attached to the diagnosis and fault tolerance of inverters to keep the stability of systems. Data-driven approaches make full use of the process data to monitor the systems, so the voltage signals are collected firstly and then preprocessed and processed by specific strategy, fault labels will be produced hereafter. When the fault labels from data-driven fault detection and diagnosis system are generated, relevant fault tolerant control method will be activated in fault tolerant control system. Some measurements are necessary to achieve the higher utilization ratio of healthy IGBTs and sinusoidal output voltage. Based on above consideration, a group isolation and reconfiguration fault tolerant control method based on data-driven methodology for cascaded seven-level inverter is proposed here to reconfigure the SPWM, in which every H-bridge is divided into two groups. The simulation of cascaded seven-level inverter is built and the result indicates that the utilization of healthy IGBTs is improved.
更多
查看译文
关键词
Data-driven, fault detection and diagnosis, fault tolerant control, IGBT fault, Group isolation and reconfiguration