Patent hemostasis of radial artery: Comparison of two methods

WORLD JOURNAL OF CARDIOLOGY(2021)

引用 0|浏览13
暂无评分
摘要
BACKGROUND Radial artery obstruction is the most common complication of coronary angiography performed via transradial access. Patent hemostasis can significantly reduce the risk of radial artery occlusion. Previous studies utilized sophisticated methods to evaluate radial artery patency. Simplified and easily applicable methods for successful patent hemostasis are currently lacking. AIM To determine which method (pulse oximeter vs the traditional radial artery palpation) is better to achieve patent hemostasis. METHODS This prospective, single center study included 299 consecutive patients who underwent coronary angiography or percutaneous coronary intervention between November 2017 and July 2019. Patients less than 18 years old, with a history of radial artery disease, or no palpable artery pulse were excluded from the study. Patients were randomly assigned to two groups. In the first group, radial artery flow was assessed by palpation of the artery during hemostasis (traditional method). In the second group, radial artery patency was estimated with the use of a pulse oximeter. Two different compression devices were used for hemostasis (air chamber and pressure valve). The primary study endpoint was the achievement of successful patent hemostasis. RESULTS The two groups (pulse oximeter vs artery palpation) had no significant differences in age, sex, body mass index, risk factors, or comorbidities except for supraventricular arrhythmias. The percentage of patients with successful patent hemostasis was significantly higher in the pulse oximeter group (82.2% vs 68.1%, P = 0.005). A lower percentage of patients with spasm was recorded in the pulse oximeter group (9.9% vs 19.0%, P = 0.024). The incidence of local complications, edema, bleeding, hematoma, vagotonia, or pain did not differ between the two groups. In the multivariate analysis, the use of a pulse oximeter (OR: 2.35, 95%CI: 1.34-4.13, P = 0.003) and advanced age (OR: 1.04, 95%CI: 1.01-1.07, P = 0.006), were independently associated with an increased probability of successful patent hemostasis. The type of hemostatic device did not affect patent hemostasis (P = 0.450). CONCLUSION Patent hemostasis with the use of pulse oximeter is a simple, efficient, and safe method that is worthy of further investigation. Larger randomized studies are required to consider its clinical implications.
更多
查看译文
关键词
Radial access, Patent hemostasis, Palpation, Oximeter, Coronary angiography, Radial artery occlusion
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要