High Residual Gradient Following a Self-Expandable Transcatheter Aortic Valve-in-Valve Implantation - Risk Factor Analysis, Outcomes, and Survival.

Brazilian journal of cardiovascular surgery(2022)

引用 0|浏览15
暂无评分
摘要
High residual transvalvular gradient after TAVI-ViV is not rare, but it does not significantly affect mortality. High residual mean gradient has a negative impact on NYHA functional class improvement after the procedure. High preoperative gradient, implantation level, and small failed bioprosthesis may predispose to increased residual gradient.
更多
查看译文
关键词
Bioprosthesis,Hear Valve Prosthesis,Myocardial Infarctation,Risk Factors,Survival Rate,Survivors