Comparison Of Transvalvular Aortic Mean Gradients Obtained By Intraprocedural Echocardiography And Invasive Measurement In Balloon And Self-Expanding Transcatheter Valves

JOURNAL OF THE AMERICAN HEART ASSOCIATION(2021)

引用 29|浏览21
暂无评分
摘要
Background Concerns about discordance between echocardiographic and invasive mean gradients after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEVs) versus self-expanding valves (SEVs) exist. Methods and Results In a multicenter study, direct-invasive and echocardiography-derived transvalvular mean gradients obtained before and after TAVR were compared as well as post-TAVR and discharge echocardiographic mean gradients in BEVs versus SEVs in 808 patients. Pre-TAVR, there was good correlation (R=0.614; P<0.0001) between direct-invasive and echocardiography-derived mean gradients and weak correlation (R=0.138; P<0.0001) post-TAVR. Compared with post-TAVR echocardiographic mean gradients, both valves exhibit lower invasive and higher discharge echocardiographic mean gradients. Despite similar invasive mean gradients, a small BEV exhibits higher post-TAVR and discharge echocardiographic mean gradients than a large BEV, whereas small and large SEVs exhibit similar post-TAVR and discharge mean gradients. An ejection fraction <50% (P=0.028) and higher Society of Thoracic Surgeons predicted risk of mortality score (P=0.007), but not invasive or echocardiographic mean gradient >= 10 mm Hg (P=0.378 and P=0.341, respectively), nor discharge echocardiographic mean gradient >= 20 mm Hg (P=0.393), were associated with increased 2-year mortality. Conclusions Invasively measured and echocardiography-derived transvalvular mean gradients correlate well in aortic stenosis but weakly post-TAVR. Post-TAVR, echocardiography overestimates transvalvular mean gradients compared with invasive measurements, and poor correlation suggests these modalities cannot be used interchangeably. Moreover, echocardiographic mean gradients are higher on discharge than post-TAVR in all valves. Despite similar invasive mean gradients, a small BEV exhibits higher post-TAVR and discharge echocardiographic mean gradients than a large BEV, whereas small and large SEVs exhibit similar post-TAVR and discharge mean gradients. Immediately post-TAVR, elevated echocardiographic-derived mean gradients should be assessed with caution and compared with direct-invasive mean gradients. A low ejection fraction and higher Society of Thoracic Surgeons score, but not elevated mean gradients, are associated with increased 2-year mortality.
更多
查看译文
关键词
Bernoulli equation, echocardiographic and invasive discordance, pressure recovery, transcatheter aortic valve replacement
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要