Quantifying Left Atrial Size In The Context Of Atrial Fibrillation Ablation: Which Echocardiographic Method Correlates To Outcome Of Pulmonary Venous Isolation?

JOURNAL OF PERSONALIZED MEDICINE(2021)

引用 1|浏览33
暂无评分
摘要
Introduction: Multiple studies have shown that left atrial (LA) enlargement is a strong predictor of poor outcome after catheter ablation of atrial fibrillation (AF). LA size is commonly approximated as the diameter in the parasternal long axis. It remains unknown whether more precise echocardiographic measurements of LA size allow for better correlation with outcome after pulmonary vein isolation (PVI). Methods and results: We performed a retrospective study of 131 consecutive patients (43 females, 60% paroxysmal AF, mean CHA2DS2-Vasc score 1.6, mean age 61 +/- 12 years) referred for PVI. Measurements of the LA were carried out by a single observer in transthoracic echocardiograms (TTE) performed prior to ablation. We calculated diameter of the LA in the parasternal long axis (PLAX), LA area in the 2- as well as 4-Chamber (CH) view. LA volume was computed using the disc summation technique (LAV) and indexed to body surface area (LAVI). Procedural and follow-up data were gathered from a prospective AF database. Ablation was performed exclusively using the second generation cryoballoon by the same operators. Follow-up visits at 3, 6 and 12 months showed freedom from AF in 76%, 73% and 73% respectively. Mean values of LA calculations were LAPLAX: 37.9 mm +/- 6.3 mm, 2CH area: 22.5 cm(2) +/- 6.7 cm(2), 4CH area: 21.4 cm(2) +/- 5.5 cm(2), LAV: 73.7 mL +/- 26.1 mL and LAVI: 36.2 mL/m(2) +/- 12.7 mL/m(2), respectively. C statistic revealed the best concordance of LAVI with outcome after 12 months (C = 0.67), LAV also exhibited a satisfactory value (C = 0.61) in comparison to surfaces in 2CH (C = 0.59) and 4CH (C = 0.57). PLAX showed the worst correlation (C = 0.51). Additionally, different binary logistic regression models identified three independent predictors of AF outcome after cryoballoon PVI: gender (OR = 0.95 per year; p = 0.01); LAV (OR = 1.3/10mL; p = 0.02) and LAVI (OR = 1.58/10 mL/m(2); p = 0.02). In all models, PLAX and area measurements were not predictive. Conclusions: Our data add further to evidence that LA size lends itself well as a predictor of PVI outcome. LAVI and LAV were independently predictive of rhythm outcome after PVI. This did not hold true for more commonly used measurements, such as PLAX diameter and surfaces of the LA, irrespective of the view chosen.
更多
查看译文
关键词
ablation, atrial fibrillation, left atrium, echocardiography
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要