Validity And Reliability Of The Computrainer Lab (Tm) During Simulated 40 And 100 Km Time-Trials

FRONTIERS IN SPORTS AND ACTIVE LIVING(2021)

引用 2|浏览1
暂无评分
摘要
The validity and reliability of the Computrainer Lab((TM)) (CT) was assessed, for the first time, using a high-precision motor-driven calibration rig during simulated variable intensity 40 and 100 km time-trials (TTs). The load patterns imposed by the CT were designed from previously published studies in trained cyclists and included multiple 1 or 4 km bursts in power output. For the 40 and 100 km TTs, cluster-based analyses revealed a mean measurement error from the true workload of respectively 0.7 and 0.9%. However, measurement errors were dependent upon the workload variations, fluctuating from 0.2 to 5.1%. Average biases between repeated trials were contained within +/- 1.1% for both TTs. In conclusion, using 40 and 100 km TTs containing 1 or 4 km bursts in power output, the present results indicate that (1) the CT can reliably be used by scientists to determine differences between research interventions; (2) the CT provides valid results of power output when data are being analyzed as a whole to derive one mean value of power output and; (3) variations in workload make it difficult to determine at any one time the veracity of the true power output produced by the athlete.

更多
查看译文
关键词
cycling, cycling ergometer, performance, validity, assessment