Radiogrametric Analysis Of The Thoracic Limb Phalanges In Arabian Horses And Thoroughbred Horses

ANIMALS(2021)

引用 6|浏览0
暂无评分
摘要
Simple Summary The aim of the research was to determine the radiogrametric features differentiating the phalanges of the thoracic limbs of Arabian horses and Thoroughbred horses including sexual dimorphism. Nine traits and three indexes were analyzed. Radiological measurements of phalanges showed that sexual dimorphism is not clearly marked and differences between breeds manifest themself mainly in the proximal phalanx measurements. None of the parameters tested in Thoroughbred horses differed significantly between males and females. The discriminant analysis enabled the correct classification of 89.33% of the proximal phalanx samples to the exact breed. This percentage was 77.33% in the case of the middle phalanx and 54.67% for the distal phalanx, respectively. The data obtained from this study can be used as a reference material for the radiogrametric evaluation of the skeleton of the manus in horses. In this study, it was aimed to determine the statistical differences between Arabian horses and Thoroughbred horses based on X-ray images of forelimb digital bones. Latero-medial X-ray images of digital bones of thoracic limbs were taken of 25 Arabian horses and 50 Thoroughbred healthy horses. The difference between males and females within the breed was statistically analyzed as well. Nine measurements and three indexes taken from phalanges of thoracic limbs were used. Thoroughbred horses did not differ significantly between sexes, as indicated by the ANOVA. For the Arabian horses, the length of the middle of the proximal phalanx (p < 0.05), the length of the middle of the middle phalanx (p < 0.001), and the length of the dorsal surface of the distal phalanx (p < 0.05) measurement points were found to be differentiated between sexes. In the analysis made between Thoroughbred horses and Arabian horses with no respect to sex, the critical measurement was the depth of the caput of the proximal phalanx. The discriminant analysis enabled the correct classification of 89.33% of the proximal phalanx samples to the exact breed. The correct classification rate was 77.33% in the case of middle phalanx and 54.67% in the case of distal phalanx. Measurement results of the distal phalanx were found to be insignificant between both breeds and sexes. The radiological measurements of digital bones showed that sexual dimorphism was not too expressed and that decisive differences were found between the breeds.
更多
查看译文
关键词
horse, phalanx, radiogrametric study, veterinary anatomy
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要