Transcatheter Mitral Valve-In-Valve-In-Valve Replacement With Transseptal Puncture In The Presence Of An Atrial Septal Occluder Device

ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES(2021)

引用 0|浏览0
暂无评分
摘要
Quite often the iatrogenic atrial septal defect created after percutaneous transcatheter mitral valve replacement procedures is closed with an atrial septal occluder device thus precluding further transseptal interventions if required. In this case report, we describe a patient who previously underwent a valve-in-valve transcatheter mitral valve replacement and iatrogenic atrial septal defect closure with an Amplatzer device, who developed severe prosthetic mitral valve stenosis. This patient required a second percutaneous valve-in-valve in-valve procedure with a transseptal puncture in the presence of an atrial septal occluder device.
更多
查看译文
关键词
2D echocardiography, atrial septal defect, bioprosthetic mitral valve stenosis, doppler echocardiography, TEE, three-dimensional echocardiography