Cardiac Resynchronization Therapy With Or Without Defibrillation In Patients With Nonischemic Cardiomyopathy A Systematic Review And Meta-Analysis

CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY(2021)

引用 12|浏览11
暂无评分
摘要
Background:Cardiac resynchronization therapy (CRT) represents a major medical advance in patients with heart failure with electrical dyssynchrony to improve symptoms, reduce hospitalization, and increase survival both in the presence and absence of implantable cardioverter-defibrillator therapy. However, among CRT-eligible patients with nonischemic cardiomyopathy (NICM), the benefit of defibrillator therapy in addition to CRT remains unclear. A systematic review and meta-analysis comparing outcomes of patients with NICM and heart failure who underwent CRT with implantable cardioverter-defibrillator (CRT-D) versus CRT-pacemaker only (CRT-P) was, therefore, performed.Methods:A literature search from inception through February 2020 was conducted in PubMed and Cochrane Review Databases for all studies reporting outcomes of CRT-D versus CRT-P in CRT-eligible patients with NICM. Studies reporting nonstratified outcomes, including patients with ischemic cardiomyopathy, were excluded. The primary end point of interest was all-cause mortality. A random-effects model using hazards ratio (HR) was used to calculate a cumulative HR for all-cause mortality. The Grading of Recommendations Assessment, Development, and Evaluation approach assessed the certainty of evidence across outcomes.Results:Of a total of 1478 potential citations, the search yielded 8 citations that met inclusion and exclusion criteria. There was one randomized controlled trial which included a subgroup of 645 CRT-eligible patients with NICM (322 with CRT-D and 323 with CRT-P). Seven observational studies representing 9944 CRT-eligible patients with NICM (6865 CRT-D implantation and 3079 with CRT-P) were included in a pooled meta-analysis. The cumulative adjusted HR for all-cause mortality for CRT-D versus CRT-P was 0.92 (95% CI, 0.83-1.03); I-2=0 though with low certainty of evidence. There may be little difference in infection and cardiac mortality between CRT-D versus CRT-P devices (HR, 0.82 [95% CI, 0.29-2.20] moderate certainty of evidence and HR, 0.68 [95% CI, 0.37-1.25], low certainty of evidence, respectively).Conclusions:In this meta-analysis, the addition of defibrillator therapy was not significantly associated with a reduction in all-cause mortality in CRT-eligible patients with NICM.
更多
查看译文
关键词
cardiac resynchronization therapy, defibrillator, heart failure, hospitalization, mortality
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要