Pericardial Tamponade Caused by Rotational Atherectomy Ablation Grinding Through a Barrier Stent Protruding From the Diagonal Artery: A Case Report.

Journal of medical cases(2021)

引用 0|浏览1
暂无评分
摘要
Rotational atherectomy (RA) has been described in case reports to be effective in ablating under-expanded stents. We present a case of calcified bifurcation lesion percutaneous coronary intervention (PCI), in which the branch stent protruding into main branch blocked the balloon getting through, and the following RA led to pericardial tamponade. The first stent was deployed from the proximal of left anterior descending artery (LAD) to the proximal of diagonal for an 80-year-old man who suffered from non-ST-elevation myocardial infarction to make a Culotte dual stent PCI. The operator failed to make balloon get through the struts protruding into LAD lumen anyway. After RA drill through the LAD lumen, it showed an excellent angiographic outcome. Stent deployment in LAD was successful, but pericardial tamponade occurred in a short time. After pericardiocentesis was performed under fluoroscopic guidance, the patient was uneventful. After 1 year, the follow-up coronary computed tomography (CT) angiography showed no in-stent restenosis, stent fracture or disrupted struts protruding outside of the vessel's outline of LAD and the first diagonal (D1). This case shows stents' RA could be dangerous in grinding across the stents' lateral hole in an unsymmetrical lumen. Although RA could be a useful remedy in the situation of under-expansion of implanted stents, the debulking should be performed for longitudinal stent ablation and cautiously performed for bifurcation lesion in which the protruding stents from side branch were unsymmetrically blocking the path.
更多
查看译文
关键词
Coronary angiography,Pericardial tamponade,Rotational atherectomy,Stent under-expansion
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要