Combined Localizer (Tm) And Intraoperative Ultrasound Localization: First Experience In Localization Of Non-Palpable Breast Cancer

IN VIVO(2021)

引用 6|浏览3
暂无评分
摘要
Background: Wire-guided localization is the gold-standard for the detection of non-palpable breast lesions, although with acknowledged limitations. The aim of this study was to evaluate the combined use of LOCalizerr (TM) (Hologic, Santa Carla, CA, USA), and intraoperative ultrasound (IOUS) for localization and surgery of non-palpable breast cancer. Patients and Methods: Patients with non-palpable breast lesions underwent localization procedure with LOCalizer (TM) and IOUS. After the placement of the marker, eight measures were made to guide the excision. LOCalizerr (TM) Pencil and IOUS were performed to obtain the distance between the dissection plane and the margins of lesions. Results: The procedure was feasible in the five enrolled patients and associated with clear oncological margins in all cases. Moreover, a high satisfaction according to Likert scale for surgeons, radiologists and patients, performing limited and tailored resections, was reported. Conclusion: Combining LOCalizerr (TM) and IOUS is an effective method for locating non-palpable breast cancer, guarantying excellent oncological and cosmetic results.
更多
查看译文
关键词
Non-palpable breast cancer, LOCalizer (TM), radiofrequency localization, intraoperative ultrasound