Screening diabetic retinopathy using an automated retinal image analysis (ARIA) system in Mexico: independent and assistive use cases

user-5f8cf9244c775ec6fa691c99(2020)

引用 1|浏览4
暂无评分
摘要
Background: The automated screening of patients at risk of developing diabetic retinopathy (DR), represents an opportunity to improve their mid-term outcome and lower the public expenditure associated with direct and indirect costs of a common sight-threatening complication of diabetes. Objective: In the present study, we aim at developing and evaluating the performance of an automated deep learning-based system to classify retinal fundus images from international and Mexican patients, as referable and non-referable DR cases. In particular, we study the performance of the automated retina image analysis (ARIA) system under an independent scheme (i.e. only ARIA screening) and two assistive schemes (i.e., hybrid ARIA + ophthalmologist screening), using a web-based platform for remote image analysis. Methods: We ran a randomized controlled experiment where 17 ophthalmologists were asked to classify a series of retinal fundus images under three different conditions: 1) screening the fundus image by themselves (solo), 2) screening the fundus image after being exposed to the opinion of the ARIA system (ARIA answer), and 3) screening the fundus image after being exposed to the opinion of the ARIA system, as well as its level of confidence and an attention map highlighting the most important areas of interest in the image according to the ARIA system (ARIA explanation). The ophthalmologists9 opinion in each condition and the opinion of the ARIA system were compared against a gold standard generated by consulting and aggregating the opinion of three retina specialists for each fundus image. Results: The ARIA system was able to classify referable vs. non-referable cases with an area under the Receiver Operating Characteristic curve (AUROC), sensitivity, and specificity of 98%, 95.1% and 91.5% respectively, for international patient-cases; and an AUROC, sensitivity, and specificity of 98.3%, 95.2%, 90% respectively for Mexican patient-cases. The results achieved on Mexican patient-cases outperformed the average performance of the 17 ophthalmologist participants of the study. We also find that the ARIA system can be useful as an assistive tool, as significant specificity improvements were observed in the experimental condition where participants were exposed to the answer of the ARIA system as a second opinion (93.3%), compared to the specificity of the condition where participants assessed the images independently (87.3%). Conclusions: These results demonstrate that both use cases of ARIA systems, independent and assistive, present a substantial opportunity for Latin American countries like Mexico towards an efficient expansion of monitoring capacity for the early detection of diabetes-related blindness.
更多
查看译文
关键词
Second opinion,Fundus (eye),Diabetic retinopathy,Receiver operating characteristic,Gold standard,Optometry,Medicine,Blindness,Controlled experiment,Retinal image
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要