Evaluation of strength and microstructure of welded pipes with wall lamination

Engineering Failure Analysis(2021)

引用 4|浏览0
暂无评分
摘要
•Welding metal with laminations leads to non-uniform load of the weld joints.•Non-uniform load results in layerwise destruction of defective areas.•Application of magnetic control is inefficient for detect laminations below 100 μm.•It is necessary to complete the ultrasonic wall thickness test throughout pipe perimeter.
更多
查看译文
关键词
Lamination,Weld,Stress-strain diagram,Defects of rolled metal,Metallography